Walls, roofs and floors: what goes where and why
Insulation is only half of it. Walls, roofs and floors perform well when every layer does its job — and the joints between them are sealed.
On this page: Timber frame wall · Wall from the inside — renovation · Pitched roof — new · Roof from above — renovation · Floor · Why the tapes matter so much · ESB
Four jobs, four layers
Every wall, roof and floor has four jobs to do. Each is done by a separate layer, and no layer does another one’s job.
The insulation keeps out the cold in winter and the heat in summer.
Without it: heat loss and overheating.
Naturheld FLEX and boards →2 · Air on the insideAn airtight layer on the room side stops warm, humid air from getting into the insulation.
Without it: the air carries moisture into the construction, it condenses and wets the insulation.
Vapour control layer or ESB + tapes →3 · Wind and rain on the outsideOutside, a naturheld board or a roofing underlay stops wind and water but lets vapour out.
Without them: wind blows through the insulation and rain wets it.
naturheld 180, LDB 0.02 →4 · StructureThe structural board braces the studs, the roof and the floor and is the base for everything else.
Without it: there is nothing to tape or fix to.
ELKA esb Plus →The rule: airtight inside, open outside. Each layer further out lets vapour through more easily than the one before, so that moisture can get out instead of collecting in the construction.
Timber frame wall
Outside, a naturheld board stops the wind, FLEX between the studs keeps the heat, and on the inside there are two good solutions.
A. ESB + 4 cm naturheld + lime plaster
ESB with taped joints braces the wall and is the airtight layer. On top — a 4 cm naturheld board and lime plaster: a warm, breathable wall with mass, without plasterboard.
- Facade: render or cladding
- naturheld 180, 40 mm — wind barrier, lets vapour out
- naturheld FLEX between the studs — heat
- ELKA esb Plus 15 mm — structure and airtightness; joints taped
- naturheld 140, 40 mm — base for the plaster
- Lime plaster
| naturheld 180, 40 mm | €21.55/m² |
| naturheld FLEX 160 mm | €34.18/m² |
| ELKA esb Plus 15 mm | €14.28/m² |
| naturheld 140, 40 mm | €18.80/m² |
| Total per m² Materials only, without labour, tapes, fixings and plaster; ex warehouse in Bulgaria. | €88.81 incl. VAT €74.01 excl. VAT |
B. VITA on battens, without ESB
Straight onto the studs — a membrane with a variable Sd value, sealed airtight. On it a batten frame (the cables run in it without piercing the membrane) and the VITA three-layer board as a finished visible wall.
- Facade: render or cladding
- naturheld 180, 40 mm — wind barrier, lets vapour out
- naturheld FLEX between the studs — heat
- Variable-Sd membrane (AIRSTOP DIVA), overlaps taped
- Batten frame — space for cables
- ELKA VITA 19 mm — visible surface
| naturheld 180, 40 mm | €21.55/m² |
| naturheld FLEX 160 mm | €34.18/m² |
| AIRSTOP DIVA | €4.75/m² |
| ELKA VITA 19 mm | €45.36/m² |
| Total per m² Materials only, without labour, tapes, fixings and battens; ex warehouse in Bulgaria. | €105.84 incl. VAT €88.20 excl. VAT |
Wall from the inside — renovation
When the facade cannot be touched — an old house, a flat, a stone wall. The board is glued over its whole area to the dry wall, without a vapour barrier: together with the capillary-active plaster it takes up moisture and returns it to the room.
naturheld 110, 40–80 mm, glued
The wall must be dry and sound; wallpaper and loose plaster are removed.
- The facade stays as it is
- Existing wall (brick, stone, adobe)
- Adhesive over the whole area
- naturheld 110, 60 mm
- Capillary-active (lime) plaster
| naturheld 110, 60 mm | €22.31/m² |
| Total per m² Materials only, without labour, tapes, fixings and plaster; ex warehouse in Bulgaria. | €22.31 incl. VAT €18.59 excl. VAT |
Pitched roof — new
FLEX between the rafters, a naturheld board above them — a second protection against rain and no thermal bridges through the rafters. Inside — a taped vapour control layer.
Insulation between and above the rafters
The board above the rafters is tongue and groove; at pitches under 15° an LDB 0.02 membrane is added on top.
- Roof tiles
- Battens and counter-battens
- naturheld 180, 60 mm, tongue and groove — above the rafters
- naturheld FLEX between the rafters
- naturheld DB Vario vapour control layer, overlaps taped
- Lining: ESB, VITA or plasterboard
| naturheld 180, 60 mm | €32.18/m² |
| naturheld FLEX 160 mm | €34.18/m² |
| naturheld DB Vario | €4.36/m² |
| Total per m² Materials only, without labour, tapes, fixings and plaster; ex warehouse in Bulgaria. | €70.72 incl. VAT €58.93 excl. VAT |
Roof from above — renovation
The old roof stays and the rooms below are not opened. The tiles come off, a membrane and a 6–8 cm naturheld board go on the old roof, then new battens and the tiles go back.
Membrane + 6–8 cm naturheld
- Roof tiles — put back
- New battens and counter-battens
- naturheld 180, 60–80 mm, tongue and groove
- naturheld LDB 0.02 membrane
- Old roof — boarding, rafters and insulation stay
| naturheld 180, 60 mm | €32.18/m² |
| naturheld LDB 0.02 | €4.64/m² |
| Total per m² Materials only, without labour, tapes, fixings and plaster; ex warehouse in Bulgaria. | €36.83 incl. VAT €30.69 excl. VAT |
In the example — 60 mm; at 80 mm the board costs €43.10/m² incl. VAT.
Floor
A warm floor that does not drum — on a concrete slab or on joists with a ventilated space below. Instead of ESB and floorboards, VITA 27 mm can go straight on — it is also the finished floor surface.
On a concrete slab
- Floorboards
- ELKA esb Plus 22 mm
- naturheld 110, 120 mm
- Concrete slab
| naturheld 110, 120 mm | €45.30/m² |
| ELKA esb Plus 22 mm | €21.43/m² |
| Total per m² Materials only, without labour and floorboards; ex warehouse in Bulgaria. | €66.73 incl. VAT €55.61 excl. VAT |
On concrete, with VITA 27 mm
Instead of ESB and floorboards — the VITA 27 mm three-layer board straight on: it carries the load and is the finished floor surface.
- ELKA VITA 27 mm — finished floor
- naturheld 110, 120 mm
- Concrete slab
| naturheld 110, 120 mm | €45.30/m² |
| ELKA VITA 27 mm | €63.50/m² |
| Total per m² Materials only, without labour; ex warehouse in Bulgaria. | €108.80 incl. VAT €90.67 excl. VAT |
Ventilated floor on joists
Joists 50 × 200 mm, with naturheld FLEX 200 mm between them. On the joists — an AIRSTOP DIVA membrane with taped overlaps (the airtight layer), on top a 35 mm naturheld 220 board and the floor finish. Below, the joists are closed with ESB and an OMEGA membrane. Checked with a condensation calculation to DIN 4108-3: within the limits. Without DIVA on top, the moisture in the lower ESB exceeds the limit — so it is essential.
- Floorboards or another finish
- naturheld 220, 35 mm — above the joists
- AIRSTOP DIVA on the joists, overlaps taped
- Joists 50 × 200 mm, naturheld FLEX 200 mm between them
- ELKA esb Plus 15 mm — under the joists
- OMEGA MONOTOP 330 membrane (330 g/m², Sd 0.12 m)
| naturheld 220, 35 mm | €19.06/m² |
| AIRSTOP DIVA | €4.75/m² |
| naturheld FLEX 200 mm | €42.72/m² |
| ELKA esb Plus 15 mm | €14.28/m² |
| OMEGA MONOTOP 330 | €7.37/m² |
| Total per m² Materials only, without labour and floorboards; ex warehouse in Bulgaria. | €88.18 incl. VAT €73.48 excl. VAT |
Without the joists and the floor finish. U ≈ 0.16 W/m²K with joists at 60 cm centres.
Work it out for your area in the calculator → · Check the wall in the generator →
Why the tapes matter so much
Wood fibre boards insulate, but they are not airtight — under DIN 4108-7 they count as porous. Airtightness comes from a separate layer on the room side: a vapour control membrane or taped boards.
That layer is only as airtight as its weakest joint. A membrane with untaped overlaps, or boards with open joints, let warm, humid air through the gaps — exactly where the insulation is coldest.
That is why the tape is not an extra but part of the layer. Tape: membrane overlaps, joints between boards, connections to walls, floor and ceiling, every pipe and cable penetration, windows, chimneys and roof windows.
The airtightness of the finished building is checked with a Blower Door test — it is easier to get it right the first time than to hunt for gaps once the lining is closed.
AIRSTOP FLEX, AIRSTOP ELASTO, TIMBERFLEX
Grommets for pipes and cablesAIRSTOP penetrations and grommets
Windows and doorsISOWINDOW tapes
Primer for dust and concreteOMEGA UNI Primer, naturheld PRIMER
naturheld FIX 60 tape (60 mm × 25 m): €26.66 incl. VAT per roll.
ESB — the board that carries and seals
- A class P5 structural board — load-bearing, for humid conditions. It braces the wall studs, the roof and the floor and is the base for the next layers.
- On the room side it can also be the airtight layer: the tongue and groove boards fit tightly, and the joints and connections are taped.
- It lets water vapour through 2.5 to 4 times more easily than OSB (µ 80/40 against 200/150) — the construction can dry out instead of holding moisture.
- Formaldehyde ≤ 0.03 ppm, no isocyanates, Blue Angel certified — suitable for living spaces.
- With tongue and groove it is also recognised as a roofing underlay board under the rules of the German roofers’ association (ZVDH).
ELKA esb Plus → · ESB vs OSB — the comparison in numbers →
What goes where — in short
| Construction | Inside | Insulation | Outside |
|---|---|---|---|
| Timber frame wall, A | ESB with taped joints + naturheld 40 mm + lime plaster | FLEX between the studs | naturheld 180 + facade |
| Timber frame wall, B | Variable-Sd membrane + battens + VITA | FLEX between the studs | naturheld 180 + facade |
| Masonry wall, renovation from inside | Capillary-active plaster | naturheld 110, glued | The facade stays |
| Masonry wall, insulated outside | The internal plaster is the airtight layer | naturheld 110 | Render |
| New pitched roof | Vapour control layer + tapes | FLEX between the rafters | naturheld 180 above the rafters (under 15° + LDB 0.02) |
| Roof, renovation from above | The rooms are not opened | The old one + naturheld 60–80 mm | LDB 0.02 under the board |
| Floor on concrete | — | naturheld 110, 120 mm | ESB 22 mm + floorboards, or VITA 27 mm straight on |
| Ventilated floor | naturheld 220, 35 mm + AIRSTOP DIVA on the joists | FLEX 200 mm between 50 × 200 joists | ESB 15 mm + OMEGA MONOTOP 330 under the joists |
| CLT wall or roof | ADB 5 on the CLT + tapes | naturheld boards | naturheld; roofs under 15° — LDB 0.02 |
Questions
Isn’t the insulation enough on its own?
No. Insulation keeps heat in only if air does not pass through it. Without an airtight layer inside, warm, humid air from the rooms gets into the insulation and the moisture condenses on the cold side; without a wind barrier outside, the wind blows through it.
What goes on the inside of a timber frame wall?
Two good solutions: ESB with taped joints, then a 4 cm naturheld board and lime plaster; or a variable-Sd membrane, a batten frame and the VITA three-layer board as a finished visible wall — then ESB is not needed.
Which tape should I use?
A system airtightness tape — not packing tape or general building tape. For membrane overlaps and board joints: AIRSTOP FLEX or naturheld FIX; for corners and connections to masonry: AIRSTOP ELASTO; for pipes and cables — ready-made grommets. Dusty surfaces and concrete are primed first.
Can the roof be insulated without opening the rooms?
Yes — from above. The tiles come off, an LDB 0.02 membrane and a 6–8 cm naturheld board go on the old roof, then new battens and the tiles go back.
OSB or ESB?
Both are structural boards. ESB lets vapour through 2.5 to 4 times more easily, has lower emissions and is equally strong in both directions. A detailed comparison is in the article “ESB vs OSB”.
Send us your construction
A drawing, a section or just the area — we reply with a proposal for the layers and a quote for all the materials within one working day.
No installer? Write to us and we will help.